Peripherals

 

The external wireless extensions designed for the Cx Monitor™ can introduce an ease of system testing never seen before.

By integrating AC voltage and power with wireless DC voltage, DC current, Temperature / Humidity and the DCx, full system integration testing has never been easier. Now all the data is stored on one device and only one software program is needed for a complete solution.

Peripheral Specifications

  • Cx w/ Host
  • Temperature/Humidity
  • Battery Tester
  • DCw
  • High Temperature
Cx and Host
  • A Cx with Host can handle up to 100 probes
  • Individual log file created for each probe
  • Porbes can be mixed and matched on the same Cx
  • Programmable log rate: 4 seconds to 30 minutes, seperate from other Cx features
  • Real-time values are viewable with Live-View
  • Data files can be graphed or exported to Excel/CSV with U-View
  • Range: Indoor up to 100 ft

Wireless TH - Single Temperature & Humidity

Temperature Probe Specifications:

  • Range: 0° - 122° Fahrenheit
  • Resolution: 0.02° Fahrenheit
  • Accuracy: ±1.5° Fahrenheit
  • 1 Reading per log entry

Humidity Probe Specifications:

  • Range: 0%-100% Relative Humidity Non-Condensing
  • Resolution: 0.03% Relative Humidity
  • Accuracy: ±2% (10%-90%) Relative Humidity ±5% Full Range
  • 1 Reading per log entry

Temperature and Humidity Probe Specifications:

  • 1 Sample per 15 second
  • Dimensions: 3" x 4.5" x 1.5" (L/H/W)
  • Battery life between 20wks - 50wks dependant on log rate

More


Wireless DX - 10 Channel DC Volts

DCx Voltage Probe Specifications:

  • 10 Channel
  • ±60 Vdc
  • Accuracy: ±0.1%
  • Noise: ±2mV
  • TC = 1.63ppm/°F
  • 1 Sample per second minimum
  • 4 Readings per log entry {Min, Max, Avg}
  • Operating Temperature: 0°C to 40°C(32°F-104°F)
  • Operating Humidity: 80% Max - Non-Condensing
  • Conforms to CAT II 150V

Only 11 Connections for 10 Batteries

Battery Connections

More

Wireless or Wired DCw - Voltage and Current Ripple

The device continuously streams wired or wireless, these values include
DC Voltage
DC Current
AC Voltage
AC Current
Watts
Voltage and Current Ripple%

Device Specifications:

• True RMS sampling @ 4kHz input frequency
• On Board LED to give connection status
• Wired (ethernet) or Wireless stream to Cx Monitor
• Temperature compensated gain increases accuracy across large temperature variations
• CAT III 600V
• Power Requirements: 24V DC 3W

4000A CT

4,000A 4.5"x2.5" ID Probe Specifications:

  • Range: 40-4,000 Adc / 28 -2,800 Aac 0-5,000 Hz
  • Operating Conditions: 14-122 °F / Max 600V
Accuracy:
  • Noise: ±2 Adc
  • 1.5% from 400-4,000 Adc
  • 2% from 40-400 Adc
  • 4% from 8-40 Adc
4000Amp

2000A CT

2,000A 2" ID Probe Specifications:

  • Range: 40-4,000 Adc / 28 -2,800 Aac 0-5,000 Hz
  • Operating Conditions: 14-122 °F / Max 600V
Accuracy:
  • Noise: ±1 Adc
  • 1.5% from 200-2,000 Adc
  • 2% from 20-200 Adc
  • 4% from 4-20 Adc
2000Amp

 

Wireless High - Single Temperature

Temperature Probe Specifications:

• 14 bit resolution 0.45°F resolution
• On Board LED to give connection status
• Cold Temperature compensated gain increases accuracy across large temperature variations
• Type K Thermocouple range (-20°F - 500°F)
• 2 week battery life at 4 second log interval
• Power Requirements: 2 AA Batteries

 

Temperature Probe Accuracy:

Thermocouple ( Typical) :
    Accuracy: 4.0°F or 0.75%, whichever is greater
    Response time: 2.9 seconds, 63.2% of a 25-77°C step change per method ASTM E839

Device:
    Accuracy: +/- 3 °F
    Resolution: 0.45°F

More


RxMS News

Links

Instructions:

Wireless.pdf

Specification Sheets:

TH and DC Voltage

DC Current

Battery Tester

DCw